ECA (Electro-Chemical Activation) electrolysis technology produces HOCl solution from just three inputs: water, pure table salt and electricity. It is the most common way of producing HOCl today, used in everything from small clinic units to industrial lines. This article explains what happens inside the electrolysis cell, why the membrane matters and which parameters need to be controlled to obtain a stable HOCl solution.

What is ECA?

ECA stands for Electro-Chemical Activation. The term is associated with research on water and solutions activated by electrolysis that began in the former Soviet Union in the late 1970s, with major contributions from engineer V. M. Bakhir’s group. In Japan, Korea and Western countries, the product of this process is usually called electrolysed water (EW) or HOCl-containing electrolysed water.

In essence, ECA is the electrolysis of a dilute sodium chloride (NaCl) solution in a cell with two electrodes. The product formed at the anode is strongly oxidising and contains available chlorine, mainly as HOCl when the pH is properly controlled. If you are not yet sure what HOCl is, you may want to read What is HOCl? How it kills microbes, applications and precautions first.

Inputs: water, salt and electricity

  • Water: usually filtered, softened or treated by reverse osmosis (RO) to remove deposits and calcium, magnesium, iron and copper ions. These metal ions both scale the electrodes and catalyse faster breakdown of HOCl after production.
  • NaCl salt: pure salt without added iodine or anti-caking agents. The salt is made into brine and fed into the electrolysis cell at a steady flow rate.
  • Electricity: a direct-current supply with controlled current and voltage. The current determines how much available chlorine is produced.

Because the inputs are so simple, the quality of the HOCl solution depends heavily on the purity of the water and salt and the stability of the equipment.

What happens inside the electrolysis cell?

When current flows through the brine, ions move towards the oppositely charged electrodes and react:

At the anode

  • Chloride ions are oxidised to chlorine gas: 2Cl− → Cl2 + 2e−
  • The chlorine immediately reacts with water to form HOCl: Cl2 + H2O → HOCl + H+ + Cl−
  • Some water is oxidised to oxygen and H+ ions, making the solution on the anode side acidic.

The solution collected from the anode chamber is called anolyte: oxidising, containing HOCl and with a high positive oxidation-reduction potential (ORP).

At the cathode

  • Water is reduced to hydrogen gas and hydroxide ions: 2H2O + 2e− → H2 + 2OH−
  • OH− ions combine with Na+ to form dilute sodium hydroxide (NaOH).

The solution from the cathode chamber is called catholyte: alkaline with a negative ORP, and usually studied for cleaning and degreasing. Catholyte is not the main disinfecting product.

Why does the membrane matter?

An electrolysis cell may or may not have a membrane between the two electrodes. This difference determines the composition of the final product:

CriterionCell without membraneCell with membrane
How it worksProducts from both electrodes mix inside the cellA semi-permeable membrane separates anolyte and catholyte
Product pHUsually slightly alkaline to alkaline when electrolysing NaCl brineAnolyte is acidic; can be adjusted to the desired range
Main form of available chlorineMainly hypochlorite (OCl−), close to dilute bleach, when electrolysing NaCl brineHOCl, when the pH is brought to about 5.0–6.5
Typical useOn-site sodium hypochlorite generators for water treatmentProducing HOCl solution for cleaning and disinfection

There is one notable exception: in Japan, slightly acidic hypochlorous acid water (pH 5.0–6.5) is usually produced by electrolysing dilute hydrochloric acid, or a mixture of hydrochloric acid and salt, in a cell without a membrane.

Review papers on electrolysed water usually classify products by pH: acidic electrolysed water (pH about 2–3, ORP above 1,100 mV), neutral electrolysed water (pH about 6.5–8, depending on the classification) and alkaline electrolysed water (pH about 10–13, negative ORP). In Japan, “hypochlorous acid water” is regulated as a food additive and divided by pH into strongly acidic (pH ≤ 2.7), weakly acidic (pH 2.7–5.0) and slightly acidic (pH 5.0–6.5) types; the slightly acidic type has been recognised since 2002.

Parameters to control

ParameterMeaning
Available chlorine concentration (ppm)The amount of disinfectant in the solution, which determines dilution and intended use
pHDetermines the ratio of HOCl to OCl−; the 5.0–6.5 range gives a high HOCl share
ORP (mV)Reflects the oxidising capacity of the solution; used for quick monitoring during operation
Conductivity, residual saltHigh residual salt can cause scaling and corrosion and leave marks on surfaces

The two numbers users see most often on labels are pH and ppm. How to understand and convert them is explained in pH and ppm: the two numbers that determine the effectiveness of an HOCl solution.

The ECA production process for HOCl solution

  1. Water treatment: filtration, softening and RO for a consistent feed water.
  2. Brine preparation: dissolve pure salt in a tank and control its concentration.
  3. Electrolysis: the brine passes through the ECA cell at set current and flow rate.
  4. Adjustment and testing: measure pH, available chlorine and ORP; adjust operating parameters if needed.
  5. Filling and storage: fill into sealed, light-limiting packaging; label with concentration, directions for use and expiry date.

Advantages and limitations of ECA technology

Advantages

  • Simple, readily available inputs: water, salt and electricity.
  • Can be produced close to where it is used, reducing transport and storage of concentrated chemicals.
  • Concentration and pH can be adjusted to the purpose.
  • After reacting, the product mainly reverts to water and dilute salt.

Limitations

  • Initial equipment investment; electrodes and membranes need regular maintenance and replacement.
  • Product quality depends on the water, the salt and operator skill.
  • HOCl is less stable than bleach, so suitable packaging, storage conditions and shelf life are needed.

The ECA system at the Bio ActiW plant

Bio ActiW Vietnam produces HOCl solution on ECA electrolysis equipment manufactured in Europe (Poland), combined with RO water treatment and brine tanks. For technology details, see the Technology page.

Frequently asked questions

Is ECA electrolysed water the same as “alkaline ionised water” for drinking?

No. Alkaline ionised water machines for drinking water are different devices that do not use brine and are not designed to produce HOCl. HOCl solution and catholyte from industrial ECA systems are not for drinking.

How does ECA differ from electrolysers that make bleach?

On-site bleach generators usually use a cell without a membrane, producing an alkaline product that is mainly hypochlorite. ECA systems that produce HOCl must control pH so that most of the available chlorine is present as HOCl. A detailed comparison of the two solutions is in HOCl vs. bleach: how are they similar and different?

Can I make HOCl at home with a mini machine?

Small electrolysers are available on the market. The concentration and pH of their output depend on the amount of salt, water quality and electrolysis time, so they are hard to keep consistent. If you use one, follow the manufacturer’s instructions exactly, check the concentration with test strips and use the solution within a short time.

Want to learn more about HOCl solution made with ECA technology? Call +84 379 688 693 or send us a request and the Bio ActiW team will get back to you shortly.

References

  1. Huang YR, Hung YC, Hsu SY, Huang YW, Hwang DF. Application of electrolyzed water in the food industry. Food Control, 2008, 19(4): 329–345. doi:10.1016/j.foodcont.2007.08.012
  2. Hricova D, Stephan R, Zweifel C. Electrolyzed water and its application in the food industry. Journal of Food Protection, 2008, 71(9): 1934–1947. doi:10.4315/0362-028x-71.9.1934
  3. Rahman SME, Khan I, Oh DH. Electrolyzed Water as a Novel Sanitizer in the Food Industry: Current Trends and Future Perspectives. Comprehensive Reviews in Food Science and Food Safety, 2016, 15(3): 471–490. doi:10.1111/1541-4337.12200
  4. Ramírez Orejel JC, Cano-Buendía JA. Applications of Electrolyzed Water as a Sanitizer in the Food and Animal-By Products Industry. Processes, 2020, 8(5): 534. doi:10.3390/pr8050534
  5. Food Safety Commission of Japan (FSC). Food additive evaluation dossier: “hypochlorous acid water” (次亜塩素酸水), 2018. fsc.go.jp